Mechanical Solutions to a Malfunctioning Heart

Weighing in at a mere 8 to 12 ounces, the human heart pumps around 2,000 gallons of blood every day. The heart is vital to our life and wellbeing; it even generates its own electrical signal. 

In this article, we discuss heart failure, a condition responsible for 14.6% of deaths in the USA, and its potential treatment options, namely, heart transplants and mechanical circulatory support devices. We will discuss the history of each, the major challenges, and the progress made in the field.  

Heart Failure and Heart Transplant

In the US, nearly 6.7 million adults (ages 20 and up) have heart failure. It occurs when the heart is unable to pump enough blood and oxygen to support the body. The blood backs up, leading to fluid buildup in undesired locations, including the lungs, legs and ankles. People suffering from heart failure often feel short of breath in daily activities or when lying down, experience fatigue, decreased appetite and face weight gain due to fluid buildup. In the later stages of heart failure, symptoms can include low blood pressure, shortness of breath, worsening kidney or liver function and dangerous heart rhythms. In severe cases, once other treatment has failed, a heart transplant is generally considered the best option. Current heart transplants have high success rates, with an average life expectancy of over 15 years. In response to limitations and challenges of heart transplants, mechanical circulatory support devices are often used as a bridge to transplantation or as a long-term therapeutic option. 

The first successful heart transplant was performed in South Africa in 1967 by Dr. Christiaan Barnard. Putting aside the ethical questions, this milestone achievement paved the way for further heart transplants. Heart transplants are considered the gold standard for treating severe heart failure. However, patients often need to wait at least 6 months for a transplant. Because any transplanted organ may be rejected by the recipient’s immune system, candidates for transplants must not have antibodies to HLA (Human Leukocyte Antigen, a group of proteins that identifies foreign materials) and they must be eligible for long-term immunosuppression (reduction of immune system function). Long-term immunosuppression can be very dangerous, with a high risk of infection and cancer. Scarcity of donor organs, necessary immunosuppression and long eligibility requirements limit the possibility of heart transplantation for many individuals. For these reasons, mechanical circulatory support devices are necessary. 

Mechanical Circulatory Support Devices: History

There are 2 types of long-term mechanical circulatory support devices: total artificial hearts and ventricular assist devices. Since no human organs are involved, these bypass the need for donor organs and the risk of donor-recipient mismatch. This is a major advantage, enabling those who cannot tolerate immunosuppression and who don’t meet the requirements for heart transplantation to receive needed circulatory support. 

The first artificial heart was implanted in Texas in 1969. Unable to recover from an aneurysm repair operation, Haskell Karp desperately needed a heart transplant. Karp accepted the artificial heart, and it kept him alive for 64 hours until a suitable donor heart was found. Sadly, Karp passed away 32 hours later from sepsis. The device damaged both the blood and kidneys, and blood clots were found. The device had not met requirements for human testing at the time. Nonetheless, two of the researchers took the device and implanted it. While showing that mechanical devices can bridge the gap until a heart transplant becomes available, this case also shows some of the major risks associated with a heart replacement. 

In 1982, Barney Clark became the first person to receive a permanent artificial heart. He suffered from cardiomyopathy, which is a weakening of the heart muscle that leads to heart failure. With his heart failing, pumping at 20% capacity, he received the Jarvik-7. It was the first operation of its kind and it was deemed successful. Clark lived another 112 days. However, his challenges at the time were vast: seizures, fluid and electrolyte imbalance and disorientation. Ultimately, he died of circulatory collapse and secondary multi-organ system failure triggered by an infection. Four other patients received this device; the longest one lived for 620 days after getting this device. Unfortunately, all died of either sepsis or blood problems, with two facing severe strokes. 

As heart transplantation became a more successful, viable option, attention shifted to developing devices that could effectively bridge the gap until heart transplantation, so most development was shifted towards LVADs (left ventricular assist device).  

LVAD

In regular heart function, the left ventricle fills with oxygenated blood. Then the heart muscle squeezes the ventricle, sending that blood through the aorta to the entire body. When the heart can’t properly eject the blood, an LVAD takes blood from the left ventricle and pumps it to the aorta. 

The main complications of LVADs are major bleeding (occurring in one third of patients), infection, stroke, blood clots and death, as well as hemolysis (damage to blood cells due to the pump) and ventricular arrhythmias. Further, since LVADs increase blood flow throughout the body, the load on the right ventricle increases, which can cause right heart failure.  

Each side effect can be traced to different design aspects. For instance, LVADs are thrombogenic, meaning they can cause blood clots. To reduce this, patients are generally prescribed blood thinners, which leads to excessive bleeding. The Heart Mate 3, the most advanced LVAD available, uses a magnetic pump, which drastically reduces the chances of blood clot formation, strokes and bleeding-related complications. 

In fact, LVADs are now considered a “destination therapy.” One clinical trial of the Heart Mate 3 found a survival rate of 88% at one year and 58% at five years in a disease process that otherwise has a median survival of under a year. It is exciting to watch how advances in LVADs have addressed these challenges and provided a life-saving option for many patients.

Other Mechanical Circulatory Support Devices

RVADs, right ventricular assist devices, function like LVADs, taking blood from the right ventricle and pumping it to the lungs to get oxygenated. They are not as common as LVADs. If both the left and right ventricles need support, a BiVAD (both an LVAD and RVAD) can be used. 

In a certain subset of patients, especially those with structural difficulty (like malfunctioning valves), LVADs, RVADs and BiVADs are not an option as VAD devices replace only the pumping functionality of the heart. A potential alternative lies in a total artificial heart, where the ventricles and valves are removed and replaced. Total artificial hearts are still under development and are looking promising. 

Much progress has been made in the treatment of severe heart failure. Currently, heart transplants, LVADs and other mechanical support mechanisms have been successful in extending patients’ lives and improving their quality of life. These technologies are constantly being researched to be safer and to address more needs. 